[의학공학] 바이오센서를 이용한 혈당량 측정에 관한 기술(영문)

  • 등록일 / 수정일
  • 페이지 / 형식
  • 자료평가
  • 구매가격
  • 2010.12.21 / 2019.12.24
  • 7페이지 / fileicon doc (MS워드 2003이하)
  • 평가한 분이 없습니다. (구매금액의 3%지급)
  • 1,200원
다운로드장바구니
Naver Naver로그인 Kakao Kakao로그인
최대 20페이지까지 미리보기 서비스를 제공합니다.
자료평가하면 구매금액의 3%지급!
이전큰이미지 다음큰이미지
목차
-Abstract
-Keywords
-Introduction
-Cantilever detection Modes of operation
-Cantilever detection Modes of detection
-Glucose and pH Sensing in Exhaled Breath Condensate
-Conclusions
-REFERENCES
본문내용
Working in the static mode, the bending arises as a consequence of a surface stress change induced by any molecular reaction which takes places on only one of the cantilever surfaces. The induced surface stress change could be positive or negative, depending on the surface deformation generated. The factors and phenomena responsible for this change is today not fully understood due to the complex equilibrium between the sensing layer, and the surrounding water molecules, the bulk solution, the target molecules, ions, etc. Interactions coming from electrostatic, hydration, steric and van der Waals forces, changes in the surface hydrophobicity or conformational changes of the adsorbed molecules play an important role in the final bending.[1],[2] The easiest and most extended model to study the surface stress produced on cantilevers is based on the work of G.G Stoney in 1909. Looking for higher accuracy, some works have presented modifications on this model, depending on the thickness or roughness of the surface.[3] Other energy-based models studied the dependence of the cantilever bending with the density of the adsorbed atoms/molecules and the properties of the substrate.[4] Stoney’ model relates the total surface stress change between the top and the bottom sides (Ds1 Ds2) with the cantilever free end displacement, Dz, the Young’ modulus, E, the Poisson coefficient, n, and the cantilever length, L, and thickness, t, by,

For sensing biomolecular interactions in the static mode, only one surface of the microcantilever must be previously biofunctionalized and this can be a complex task especially when arrays of microcantilevers are employed.
In contrast to the static case, the dynamic mode does not require the functionalization of only one cantilever surface, as the cantilever resonance frequency change depends on the total mass adsorbed on both sides. In this mode, the microcantilever is used as a microbalance and extremely high sensitivities can be obtained (in the attogram regime), overcoming other similar and well-known mass detectors, such as the quartz crystal microbalance (QCM).[5] In first approximation cantilevers behave like a harmonic oscillator, and the mass change on a rectangular cantilever will produce a reduction on the resonance frequency, which can be estimated from:

where f0 and f1 are the fundamental resonance frequency before and after the mass adding, respectively.
Recent studies have demonstrated that surface stress can induce a microcantilever stiffness change, due to strain-dependent surface stress (elasticity), which can cancel or make negligible the resonance frequency change due to the added mass.[6–8] The induced cantilever stiffness change can produce a resonance frequency shift as high as the added mass, but increasing the microcantilever resonance frequency, depending on the attached protein density and thickness and the cantilever length.[9] Actually, this is one of the questions to be solved in order to avoid errors in the characterization of biological agents, being necessary to identify and detach the frequency shifts coming from the added mass and the stiffness changes.[10]
When working in the dynamic mode, the resolution of the system, Df, is determined by the quality factor, Q, following the expression △f=f/Q. The quality factor quantifies the energy dissipation and is defined as the ratio between the mechanical energy accumulated and dissipated per vibration cycle. Under liquids environments, the quality factor shifts toward much lower values than in air, due to the damping effect of the viscous surroundings, which decrease abruptly the overall sensitivity. For that reason, this way of operation is more difficult to implement and, until recently, most of the cantilever biosensors were based on the static mode.

Cantilever detection Modes of detection
In the optical lever scheme, the cantilever free end movement is detected by measuring the reflected laser beam displacement into a position-sensitive photodetector (PSD).
자료평가
    아직 평가한 내용이 없습니다.
회원 추천자료
  • [과학기술과 사회] 과학기술의 발달에 따른 사생활의 침해 및 사례 분석
  • 기술개발을 진행하고 있다. 또 미국 이스마트테크놀러지의 국내 법인인 이스마트코리아도 스마트카드에 초박형 생체인식 지문센서와 자체 지문인식 모듈을 탑재해 카드자체로 본인임을 확인할 수 있는 지문인식모듈 탑재카드를 내놓고 시장개척에 나서고 있다.이밖에 스마트카드제조업체인 KDN스마텍은 얼굴인식 기술보유업체인 퍼스텍과 생체인식 공동사업 추진을 위한 제휴를 맺고 생체인식을 이용한 출입국시스템 사업과 생체인식 스마트카드

  • 인공지능과 인간강화
  • 기술적 업그레이드가 게놈 프로젝트의 결과와 결합되면서 의학계에서 혁명적 변화가 시작되었다. 이러한 이유로 인간들은 사이보그가 되기 위해 두뇌 이식으로 자신의 기능을 업그레이드시키기를 원하게 되었다. 유전자 지도(gene mapping)는 누가 유전적으로 완벽한 배우자가 될지를 정확하게 분석하는 출산의 목적으로 사용된다. 놀랄 것도 없지만, 이러한 부부 사이에서 태어난 자녀들이 인생에서 확률적으로 높은 성공기회를 갖는다는 것이 알려졌을

  • 의료산업 동향 레포트
  • 의학연구센터, 생물자원센터, 임상연구센터, 미니돼지연구센터 등 6개 시설을 연차적으로 건립할 계획을 수립하는 등 대대적인 시설확충에 나서고 있다. 충북테크노파크 보건의료산업센터도 산학연 네트워크 구축을 통한 바이오산업 육성에 적극 나서고 있다.이처럼 오창 과학산업단지가 바이오 연구기관과 관련 기업들로부터 인기를 끄는 것은 내년 말 조성될 청원군 오송 생명과학단지와 자동차로 10여분 거리에 위치한데다 생명공학기술(BT)산

  • 리소그래피2
  • 기술기본계획을 세우면서 나노를 중점 육성분야로 선정한데 이어 미국과의 경쟁에서 우위에 있는 소자나 재료에 연구역량을 집중하고 있다. 유럽은 상대적으로 앞서 있는 의학이나 생물학과 관련된 나노 바이오에 투자가 몰리고 있다.우리나라도 2001년 7월 나노기술종합발전계획을 마련한 뒤 지난달 27일 ‘나노기술개발촉진법 시행령’을 공포해 연구에 박차를 가하고 있다. 나노기술을 이용한 반도체 부문에서는 이미 핵심특허에서 삼성이 IBM에 이

  • [생물] 미생물의 산업적 이용
  • 공학을 통해 직간접으로 미생물의 신세를 지지 않은 사람도 드물다. 병원약국에서 팔리는 50여종 안팎의 항생제중 약 80%는 미생물에서 나왔다. 한국과학기술원 김선창 교수는 “항생제 한 종류의 세계시장이 적어도 연간 수천억원 규모다. 최근 미생물 연구가 불붙는데는 신물질 하나만 개발해도 돈방석에 올라앉을 수 시장여건이 조성돼있기 때문”이라고 말했다. 3) 초고온성 미생물의 이용 초고온 원시생물 고밀도 번식/“지구

사업자등록번호 220-06-55095 대표.신현웅 주소.서울시 서초구 방배로10길 18, 402호 대표전화.02-539-9392
개인정보책임자.박정아 통신판매업신고번호 제2017-서울서초-1806호 이메일 help@reportshop.co.kr
copyright (c) 2003 reoprtshop. steel All reserved.